📚 Exam by Category
▾
Objective Questions

Latest RPSC Senior Scientific Officer Exam Question (Objective Questions), MCQ in English

Subjects : Concerned Subject

Question Bank RPSC Senior Scientific Officer (Narcotics Division) Exam - English
Back to Exam

Concerned Subject

Question 1Single Answer
Which classical method is most suitable for macro-level determination of chloride in a seized narcotic salt sample?
  1. A
    Argentometric titration
  2. B
    Complexometric titration
  3. C
    Redox titration
  4. D
    Kjeldahl method
Question 2Single Answer
When should an analyst prefer instrumental analysis over classical titrimetry for narcotics purity determination?
  1. A
    When high throughput is not needed
  2. B
    When sample size is > 5 g
  3. C
    When only visual endpoint is required
  4. D
    When the analyte is present at trace / ppm level
Question 3Single Answer
The primary reason for choosing HPLC over titration for heroin base purity is?
  1. A
    Selectivity and ability to separate structurally similar impurities
  2. B
    Lower equipment cost
  3. C
    Simpler calibration
  4. D
    Faster analysis time for macro samples
Question 4Single Answer
According to ISO/IEC 17025:2017, method validation is mandatory when?
  1. A
    Only for trace analysis
  2. B
    Only for new instruments
  3. C
    A non-standard method is used or when a standard method is modified
  4. D
    Only when the laboratory is accredited
Question 5Single Answer
The term LOD (Limit of Detection) is defined as the lowest amount of analyte that can be?
  1. A
    Reported as zero
  2. B
    Quantified with acceptable precision and accuracy
  3. C
    Detected with 100% certainty
  4. D
    Detected with a stated confidence level but not necessarily quantified
Question 6Single Answer
LOQ (Limit of Quantitation) is typically calculated as?
  1. A
    3 x standard deviation of the response / slope
  2. B
    10 x standard deviation of the response / slope of calibration curve
  3. C
    2 x standard deviation / slope
  4. D
    5 x standard deviation / slope
Question 7Single Answer
In narcotics reporting, when the concentration is below LOQ but above LOD, the result should usually be reported as?
  1. A
    Zero
  2. B
    Not detected
  3. C
    Quantified value with high uncertainty
  4. D
    Detected / present but not quantified
Question 8Single Answer
Which document must be readily available in the laboratory when handling acetic anhydride for heroin synthesis investigation?
  1. A
    Calibration certificate of balance
  2. B
    Certificate of Analysis of the reagent
  3. C
    Safety Data Sheet (SDS / MSDS)
  4. D
    Method SOP only
Question 9Single Answer
Acetic anhydride is classified under which UN hazard class for transport?
  1. A
    Class 8 (Corrosive) + subsidiary risk Class 3 (Flammable)
  2. B
    Class 3 only
  3. C
    Class 6.1 only
  4. D
    Class 9 only
Question 10Single Answer
The preferred classical method for macro-level determination of morphine in opium is?
  1. A
    Non-aqueous titration
  2. B
    Iodometric titration
  3. C
    Gravimetry as morphine hydrochloride
  4. D
    Complexometry
Question 11Single Answer
In ISO/IEC 17025, "decision rule" is required when reporting results near a specification limit. The default rule is?
  1. A
    Never report uncertainty
  2. B
    Guard band of 2x expanded uncertainty
  3. C
    Always report as compliant
  4. D
    Simple acceptance (without guard band) unless otherwise specified
Question 12Single Answer
Which validation parameter evaluates how close the measured value is to the true value?
  1. A
    Specificity
  2. B
    Precision
  3. C
    Trueness / accuracy
  4. D
    Linearity
Question 13Single Answer
The parameter that assesses the closeness of agreement between independent test results obtained under stipulated conditions is?
  1. A
    Precision
  2. B
    Accuracy
  3. C
    Specificity
  4. D
    Robustness
Question 14Single Answer
Repeatability is a measure of precision under?
  1. A
    Different laboratories
  2. B
    Same operator, same instrument, short interval of time
  3. C
    Different days
  4. D
    Different instruments
Question 15Single Answer
Reproducibility is a measure of precision between?
  1. A
    Same laboratory
  2. B
    Different laboratories
  3. C
    Same operator
  4. D
    Same day
Question 16Single Answer
In GC-MS analysis of seized cocaine, the validation parameter "selectivity" ensures?
  1. A
    Low LOD
  2. B
    No interference from matrix or other drugs at the retention time / m/z of interest
  3. C
    High linearity
  4. D
    Fast analysis
Question 17Single Answer
The most common internal standard used in quantitative GC-MS of amphetamines is?
  1. A
    Caffeine
  2. B
    Deuterated analog (e.g. methamphetamine-D14)
  3. C
    Naphthalene
  4. D
    Anthracene
Question 18Single Answer
When reporting the purity of heroin HCl, the uncertainty should be expressed at?
  1. A
    No uncertainty required
  2. B
    k=1 (68%)
  3. C
    k=3 (99%)
  4. D
    Coverage factor k=2 (Approx.95% confidence)
Question 19Single Answer
The preferred method for trace-level detection of fentanyl in seized samples is?
  1. A
    Flame photometry
  2. B
    Titrimetry
  3. C
    Gravimetry
  4. D
    LC-MS/MS
Question 20Single Answer
In method validation, the term "robustness" refers to?
  1. A
    The cost of the method
  2. B
    The ability to detect low concentrations
  3. C
    The linearity of the calibration curve
  4. D
    The capacity of the method to remain unaffected by small deliberate variations
Question 21Single Answer
The term "ruggedness" in analytical method validation is similar to?
  1. A
    Specificity
  2. B
    Repeatability
  3. C
    Accuracy
  4. D
    Reproducibility (between laboratories)
Question 22Single Answer
According to ISO/IEC 17025, calibration of analytical balances must be traceable to?
  1. A
    Manufacturer certificate only
  2. B
    National / international standards
  3. C
    Internal lab standard
  4. D
    No traceability required
Question 23Single Answer
The primary safety precaution when handling acetic anhydride is?
  1. A
    Use in fume hood, wear gloves, goggles and face shield
  2. B
    Open bench handling
  3. C
    No special precaution
  4. D
    Only gloves required
Question 24Single Answer
The flash point of acetic anhydride is approximately?
  1. A
    >100 degree C
  2. B
    49 degree C (flammable liquid category 3)
  3. C
    <23 degree C
  4. D
    No flash point
Question 25Single Answer
In classical analysis, the endpoint of iodometric titration for heroin purity is indicated by?
  1. A
    Phenolphthalein pink
  2. B
    Starch-iodine blue-black colour disappearance
  3. C
    Methyl orange red
  4. D
    No indicator
Question 26Single Answer
The gravimetric factor for morphine in opium analysis is used when precipitating as?
  1. A
    Morphine base
  2. B
    Morphine hydrochloride or picrate
  3. C
    Morphine sulfate
  4. D
    No precipitation
Question 27Single Answer
For trace-level cocaine in biological matrices, the preferred extraction technique is?
  1. A
    No extraction
  2. B
    Liquid-liquid extraction only
  3. C
    Solid-phase extraction (SPE)
  4. D
    Distillation
Question 28Single Answer
In ISO/IEC 17025, the laboratory shall have a procedure for?
  1. A
    Only calibration
  2. B
    Handling of nonconforming work
  3. C
    Only validation
  4. D
    No procedure
Question 29Single Answer
The term "measurement uncertainty" in narcotics reporting is required by?
  1. A
    No requirement
  2. B
    Only GLP
  3. C
    ISO/IEC 17025 and Eurachem Guide
  4. D
    Only USP
Question 30Single Answer
When LOD is calculated using signal-to-noise ratio, the common S/N ratio used is?
  1. A
    10:1
  2. B
    3:1
  3. C
    2:1
  4. D
    5:1
Question 31Single Answer
For LOQ, the common signal-to-noise ratio is?
  1. A
    20:1
  2. B
    3:1
  3. C
    2:1
  4. D
    10:1
Question 32Single Answer
The most common way to determine LOD/LOQ in chromatography is?
  1. A
    Based on standard deviation of the blank / low-level response
  2. B
    Visual inspection
  3. C
    No determination
  4. D
    Only calibration
Question 33Single Answer
1% for some precursors), the decision rule should include?
  1. A
    Expanded uncertainty
  2. B
    No uncertainty
  3. C
    Only LOD
  4. D
    Only LOQ
Question 34Single Answer
The handling of acetic anhydride requires storage in?
  1. A
    Cool, dry, well-ventilated place away from oxidizers and bases
  2. B
    Open shelf
  3. C
    Direct sunlight
  4. D
    No special storage
Question 35Single Answer
Acetic anhydride reacts violently with?
  1. A
    No reaction
  2. B
    Air
  3. C
    Nitrogen
  4. D
    Water (exothermic hydrolysis)
Question 36Single Answer
In classical macro-analysis of methamphetamine, the preferred method is?
  1. A
    Non-aqueous potentiometric titration
  2. B
    Gravimetry
  3. C
    Spectrophotometry
  4. D
    No method
Question 37Single Answer
The term "specificity" in method validation means?
  1. A
    Ability to measure the analyte in the presence of interferences
  2. B
    Ability to detect low levels
  3. C
    Linearity
  4. D
    Precision
Question 38Single Answer
The term "linearity" in method validation refers to?
  1. A
    Only at low levels
  2. B
    No relationship
  3. C
    Only at high levels
  4. D
    Proportional relationship between analyte concentration and response
Question 39Single Answer
The calibration curve in narcotics analysis is usually?
  1. A
    Only linear
  2. B
    Linear or quadratic
  3. C
    Exponential
  4. D
    Logarithmic
Question 40Single Answer
The most common detector in HPLC for narcotics is?
  1. A
    Flame ionization
  2. B
    UV-Vis / PDA detector
  3. C
    Thermal conductivity
  4. D
    No detector
Question 41Single Answer
In GC analysis of volatile narcotics like amphetamines, the preferred detector is?
  1. A
    Fluorescence detector
  2. B
    UV detector
  3. C
    Flame Ionization Detector (FId) or Mass Spectrometer (MS)
  4. D
    No detector
Question 42Single Answer
The internal standard method in quantitative analysis is used to?
  1. A
    No correction
  2. B
    Increase signal
  3. C
    Decrease LOD
  4. D
    Correct for losses during extraction and injection variability
Question 43Single Answer
The external standard method is suitable when?
  1. A
    Matrix effects are negligible and injection reproducibility is high
  2. B
    Matrix is complex
  3. C
    Losses are high
  4. D
    No calibration
Question 44Single Answer
In ISO/IEC 17025, proficiency testing is?
  1. A
    Required for accredited laboratories to demonstrate competence
  2. B
    Optional
  3. C
    Only for calibration
  4. D
    No requirement
Question 45Single Answer
The term "bias" in analytical chemistry refers to?
  1. A
    Systematic error
  2. B
    Random error
  3. C
    No error
  4. D
    Only precision
Question 46Single Answer
The term "accuracy" is the combination of?
  1. A
    Trueness + precision
  2. B
    Only trueness
  3. C
    Only precision
  4. D
    No combination
Question 47Single Answer
In narcotics casework, the chain of custody is maintained to?
  1. A
    Increase speed
  2. B
    Ensure integrity and admissibility of evidence in court
  3. C
    Decrease cost
  4. D
    No purpose
Question 48Single Answer
The preferred method for moisture determination in heroin samples is?
  1. A
    Gravimetric drying
  2. B
    Karl Fischer titration
  3. C
    Oven drying
  4. D
    No determination
Question 49Single Answer
In classical analysis of cocaine, the titrimetric method uses?
  1. A
    NaOH
  2. B
    Perchloric acid in non-aqueous medium
  3. C
    KMnO4
  4. D
    Iodine
Question 50Single Answer
In method validation, the term "recovery" is used to evaluate?
  1. A
    Specificity
  2. B
    Precision
  3. C
    Extraction efficiency / trueness
  4. D
    LOD
Important Questions Package

RPSC Senior Scientific Officer Exam Online Question Bank Package

Buy RPSC Senior Scientific Officer Important Questions, MCQ, question answer in Hindi & English. It will help you to score high marks in RPSC Senior Scientific Officer question bank 2026 in Online, PDF & Print study material.

+ Free Monthly Current Affairs, GK & more PDF Download
Sr.Package NameAmount
1.RPSC Senior Scientific Officer (DNA Division) Exam - Hindi
Description : 1000 Questions with Answers
₹101 [₹500]
2.RPSC Senior Scientific Officer (DNA Division) Exam - Hindi
Description : 2000 Questions with Answers
₹151 [₹500]
3.RPSC Senior Scientific Officer (DNA Division) Exam - English
Description : 1000 Questions with Answers
₹101 [₹500]
4.RPSC Senior Scientific Officer (DNA Division) Exam - English
Description : 2000 Questions with Answers
₹151 [₹500]
5.RPSC Senior Scientific Officer (Serology Division) Exam - Hindi
Description : 1000 Questions with Answers
₹101 [₹500]
6.RPSC Senior Scientific Officer (Serology Division) Exam - Hindi
Description : 2000 Questions with Answers
₹151 [₹500]
7.RPSC Senior Scientific Officer (Serology Division) Exam - English
Description : 1000 Questions with Answers
₹101 [₹500]
8.RPSC Senior Scientific Officer (Serology Division) Exam - English
Description : 2000 Questions with Answers
₹151 [₹500]
9.RPSC Senior Scientific Officer (Narcotics Division) Exam - Hindi
Description : 1000 Questions with Answers
₹101 [₹500]
10.RPSC Senior Scientific Officer (Narcotics Division) Exam - Hindi
Description : 2000 Questions with Answers
₹151 [₹500]
11.RPSC Senior Scientific Officer (Narcotics Division) Exam - English
Description : 1000 Questions with Answers
₹101 [₹500]
12.RPSC Senior Scientific Officer (Narcotics Division) Exam - English
Description : 2000 Questions with Answers
₹151 [₹500]
13.RPSC Senior Scientific Officer (Biology Division) Exam - Hindi
Description : 1000 Questions with Answers
₹101 [₹500]
14.RPSC Senior Scientific Officer (Biology Division) Exam - Hindi
Description : 2000 Questions with Answers
₹151 [₹500]
15.RPSC Senior Scientific Officer (Biology Division) Exam - English
Description : 1000 Questions with Answers
₹101 [₹500]
16.RPSC Senior Scientific Officer (Biology Division) Exam - English
Description : 2000 Questions with Answers
₹151 [₹500]
17.RPSC Senior Scientific Officer (Chemistry Division) Exam - Hindi
Description : 1000 Questions with Answers
₹101 [₹500]
18.RPSC Senior Scientific Officer (Chemistry Division) Exam - Hindi
Description : 2000 Questions with Answers
₹151 [₹500]
19.RPSC Senior Scientific Officer (Chemistry Division) Exam - English
Description : 1000 Questions with Answers
₹101 [₹500]
20.RPSC Senior Scientific Officer (Chemistry Division) Exam - English
Description : 2000 Questions with Answers
₹151 [₹500]
21.RPSC Senior Scientific Officer (DNA Division) Exam - Hindi
Description : 1000 Question & Answer Download in PDF (Send by Email)
₹151 [₹450]
22.RPSC Senior Scientific Officer (DNA Division) Exam - English
Description : 1000 Question & Answer Download in PDF (Send by Email)
₹151 [₹450]
23.RPSC Senior Scientific Officer (Serology Division) Exam - Hindi
Description : 1000 Question & Answer Download in PDF (Send by Email)
₹151 [₹450]
24.RPSC Senior Scientific Officer (Serology Division) Exam - English
Description : 1000 Question & Answer Download in PDF (Send by Email)
₹151 [₹450]
25.RPSC Senior Scientific Officer (Narcotics Division) Exam - Hindi
Description : 1000 Question & Answer Download in PDF (Send by Email)
₹151 [₹450]
26.RPSC Senior Scientific Officer (Narcotics Division) Exam - English
Description : 1000 Question & Answer Download in PDF (Send by Email)
₹151 [₹450]
27.RPSC Senior Scientific Officer (Biology Division) Exam - Hindi
Description : 1000 Question & Answer Download in PDF (Send by Email)
₹151 [₹450]
28.RPSC Senior Scientific Officer (Biology Division) Exam - English
Description : 1000 Question & Answer Download in PDF (Send by Email)
₹151 [₹450]
29.RPSC Senior Scientific Officer (Chemistry Division) Exam - Hindi
Description : 1000 Question & Answer Download in PDF (Send by Email)
₹151 [₹450]
30.RPSC Senior Scientific Officer (Chemistry Division) Exam - English
Description : 1000 Question & Answer Download in PDF (Send by Email)
₹151 [₹450]
31.RPSC Senior Scientific Officer (DNA Division) Exam Question Bank Book - Hindi
Description : 1000 Question with Answer (Printed Material)
₹450 [₹800]
32.RPSC Senior Scientific Officer (DNA Division) Exam Question Bank Book - English
Description : 1000 Question with Answer (Printed Material)
₹390 [₹600]
33.RPSC Senior Scientific Officer (Serology Division) Exam Question Bank Book - Hindi
Description : 1000 Question with Answer (Printed Material)
₹450 [₹800]
34.RPSC Senior Scientific Officer (Serology Division) Exam Question Bank Book - English
Description : 1000 Question with Answer (Printed Material)
₹390 [₹600]
35.RPSC Senior Scientific Officer (Narcotics Division) Exam Question Bank Book - Hindi
Description : 1000 Question with Answer (Printed Material)
₹450 [₹800]
36.RPSC Senior Scientific Officer (Narcotics Division) Exam Question Bank Book - English
Description : 1000 Question with Answer (Printed Material)
₹390 [₹600]
37.RPSC Senior Scientific Officer (Biology Division) Exam Question Bank Book - Hindi
Description : 1000 Question with Answer (Printed Material)
₹450 [₹800]
38.RPSC Senior Scientific Officer (Biology Division) Exam Question Bank Book - English
Description : 1000 Question with Answer (Printed Material)
₹390 [₹600]
39.RPSC Senior Scientific Officer (Chemistry Division) Exam Question Bank Book - Hindi
Description : 1000 Question with Answer (Printed Material)
₹450 [₹800]
40.RPSC Senior Scientific Officer (Chemistry Division) Exam Question Bank Book - English
Description : 1000 Question with Answer (Printed Material)
₹390 [₹600]
Back to Exam